CONTROL SYSTEM ELECTRICITY CONSUMPTION OF LIGHTING.
Electricity is expensive, and will be even more expensive. Spend on it, and increasing amounts of light. It is often the case that plant, or derelict hypermarket parking is brilliantly illuminated, and thousands or even hundreds of thousands of kilowatts escape uselessly, as per buck gives a tremendous amount.
Experts warn of the impending energy crisis of energy shortage in many countries throughout the world. So energy conservation is becoming a global problem, and already an economic and environmental problem for many cities, municipalities and industrial plants. Currently operated lighting systems, in spite of meeting their basic function does not ensure that the requirements of efficiency, reliability, ease of control and efficiency.
Besides the typical faults (no lights flash) are difficult to detect damage to a network, or devastation controls. Therefore, to minimize such situations, or even eliminate them we offer you a control system of electric energy consumption.
Light sources are designed to operate at a supply voltage of ~ 230V ± 10%. In our devices, introduced a power reduction, achieved by reducing and controlling voltage light sources. The level of savings depends on the lighting infrastructure, the parameters of the mains and practice ranges from 20% to 30%.
Technical Description
ECO driver is used to reduce the effective supply voltage single-phase lighting circuit. Used as elements of executive power IGBT transistors, which are controlled by a microprocessor control unit, a co-driver ECOS. This allows a smooth adjustment to the current load, eliminating the sudden jumps in the amplitude of the power switch and ensure the ongoing stability of output voltage.
Voltage regulation is the trimming of the voltage on sionusoidy descending slope, while its behavior as it is the first (0 º -90 º and 180 º -270 º) phase accumulation of the course. Behavior of the incremental slope is essential for the proper ignition of discharge lamps in each cycle of AC voltage. Thanks to the power tubes can be reduced to a greater extent, without causing them fades. Circuits are then incorporated into the work as "mild", ie when value instantaneous voltage is zero, which greatly relieves the switches, as well as the lamp current from the stroke.
Thanks to its application can be obtained from the savings resulting from a reduction in input power by lighting circuit. System exists in several versions, allowing for use in lighting circuits with load: from 10A to 40A per phase.
The device operates in automatic mode according to a given program. ECO driver works with all types of light sources, with the exception of light sources with electronic ingniters. System has developed diagnostic system of all components .. The device is controlled by a microprocessor which adjusts in real-time operation of the controller parameters to the load and other parameters of the lighting circuit.

Graph without reducing the lamp voltage (black) and during the reduction of power (green).
Circuits with multi-point control of lighting circuits and undistributed eg office buildings, hotels, dormitories and unstable lighting installations controlled by microprocessors offer drivers Écot transformer. Ask the driver to act in time, and adjust the output voltage, the transition voltage from line voltage to a specified voltage reduction, the reading voltage and current, critical state registration, etc.
Écot drivers are available in two versions. Version of the driver to ask the action in time and to regulate the output voltage, a smooth transition from line voltage to a specified voltage reduction, the reading voltage and current, critical records of a simplified version, etc., after the time adjustable using a standard Timer, sharply reduces the output voltage of 20V, 25V or 30V (set during installation). In addition, both versions allow simple switching device in BYPASS mode.Devices are present in several versions to make the application in the lighting circuits for loads: from 10A to 160A in single phase or from 10A to 63A three-phase version.
In the event of fault conditions in the mains switch is in the so-called mode. BYPASS - supply voltage is switched from input to output directly to the system without drivers.
The average time of return on investment ranges from eighteen to twenty-four months, and the savings that can be obtained from the lighting circuits range from 20% to 30%.
The driver produced by our company has a patent application number P379404.
Application drivers include:

The working time of the light source without the use of a reduction in working time compared to using the power reduction is increased by over 100% and amounts to 24,000 hours. Without reducing this time is less than 12,000 hours.
How to connect the ECO
How to connect the Écot
Écot way to connect devices with the possibility of integration with the control system
ECOS controls the operation of the system and allows to optimize costs and efficiently manage electricity on lighting circuits. Carries out the task of reviewing eight independently configurable lighting zones. These outputs can be set in one of several modes of operation. The controller can work in append mode lighting pronounced earlier time. You can also set options astronomical clock which results in annexing illuminate the sunset time and disable it at sunrise. In addition, the driver has an input count pulse. It is equipped with real time clock RTC, the user interface in the form of buttons and LCD display.
The device has a built-in GSM modem and Bluetooth module, which allows for quick and easy configuration of the device by mobile phone or computer from the database. In this case, the driver can set the parameters for a closed cabinet.
The controller has a non-volatile memory that stores all the parameters of a lighting system, ie states of counters, scales, and the value of output currents, voltages and power.
The program database is used to control, monitoring, analysis of energy consumption and costs. The program can be installed on any computer having a GSM modem. The program lets you create charts, energy, power, illumination time, cost, and others. There is also a map on which is shown the location of cabinets lighting along with their current status. The database program allows for easy, fast and flexible process control and monitoring of street lighting.
The benefits of using the system for saving, monitoring and control of lighting circuits:
Advantages of ECO drivers:
Economic benefits:
Environmental benefits:
The area uses the system to save, control and monitoring of the lighting circuits:
The proposed devices can be used anywhere where there are lighting circuits consisting of any sources of light except with electronic ignition systems powered by voltage or 230V ~ ~ 400V.The devices are dedicated for use in various types of lighting installations.
Area of use:
Modernize or mention of street lighting cabinets bear only the cost of investment. By installing the above / in cabinets made by our drivers also save on electricity and we care about the environment and pay the costs incurred during the period from 18 to 36 months.